Ace
Bidet |
|
|
 |

|
|
|
|
|
|
How
to Connect Cold Water to Bidet
- Turn
off Water Supply Valve(C)
- Detach
Toilet Water Supply Line(E) from
Water Supply Valve(C)
In case of Flexible Hose(3/8")
exists.
Only release the bottom part of
existing Flexible hose(3/8").
Need not detach it.
In case of Flexible Hose(1/2")
exists.
Need not detach it, but please ask
our Head office or Local Agent to
change Adapter(3/8") to
Adapter(1/2").
- Install
Cold Water Adapter(3/8")
between Water Supply
Valve(3/8") and Flexible
hose(3/8") provided.
- Connect
the Water Tube(K) of Bidet to the
outlet of the Adapter and tighten
properly.
- Open
the Water Supply Valve(C).
- Cold Water can be connected to a
water supply valve under the
Washstand.
1) All instructions are the same as
for Hot Water.
2) Parts(Flexible hose(B)) is same
as for Hot Water. Buy them at a
Hardware stores or our Sales shops.
|
|
How
to Connect Hot Water to Bidet
- Turn
off Water Supply Valve(C).
- Replace
existing Water Supply Line(E) with
Flexible Hose(B) provided.
- 3Types of case as below -
- Install
Adapter (B) between Water Supply
Valve(C) and Flexible Hose(B).
- Connect
the Water Tube(K) of Bidet to the
outlet of the Adapter(B) and tighten
properly.
- Open
the Water Supply Valve(C) and your
Bidet is ready to use.
If
your existing Water Supply Line(E) is
- In
case of Flexible Hose(3/8")
exists
Only release the bottom part of
existing Flexible Hose.
Need not detach it and available,
and install Adapter(B) between Water
Supply Valve(C) and existing
Flexible hose.
- In
case of Flexible Hose(1/2")
exists
All process is same as in case of
Flexible Hose(3/8"), but
Adapter spec should be changed to
1/2"(Ask our sales shop to
change).
- In
case of PVC, COPPER, or Steel Pipe
exists(pic-4)
1) Release the bottom part of
existing Pipe.
2) Cut the bottom of existing Pipe
by PIPE CUTTER propery, and connect
to Flexible Hose(B).
** Warning for
using Coopper Ring
Connect
Adapter to Flexible Hose(B)
in advance, and fasten
Flexible Hose (B) and
existing Pipe Nut with
Copper Ring.
Copper Ring can be pressed
only one time. Reuse is
impossible. |
|
PVC, COPPER, STEEL
PIPE EXISTS

|
|
Water
pressure control (very important)
The
cold/hot control valve of adapter (K)
should be adjusted and set after testing
so the pressure is balanced. Excessive
pressure is not beneficial. Alter the
pressure to a sufficient level.
Warning
Please
do not full oopen Hot Water Adapter
Control part(K). Adjust at the
reasonable mild temperature, may burn
too hot water after shower. House Hot
water may be changeable.
Position
Control
- Control
the center by adjusting to the right
and left.
- Adjust
the position by moving back and
forth in order to spray the anus.
- To
prevent slip of position, please
insert the sponge pad between the
toilet and Bidet.
In
Case of Large Toilet
Open
the nozzle and move it to the side. At
this time, pull the inside hose taut and
attach it firmy to the nozzle(Use Bond).
Attach the toilet seat to the farthest
thome of the Bidet's seat combination
opening
(In an "L" shape).
Correct
Usage

- Turn
on the Drain Control Knob to remove
all cold water from the hot water
pipe while using the toilet for a
hot water washing. (HS-3000/2000K)
- Turn
off the Drain Control Knob and
adjust the water temperature at the
adequate level.
- Wash
your posterior area raising water
pressure slowly with the water
pressure control knob and give a
massage with strong water for 2-3
minutes.
- If
the water pressure is powerful, the
water penetrates deep into the large
intestines removing gas and
excrement remains, preventing
constipation.
- Water
enters into women's genitals,
allowing better washing towards the
back.
- Rinse
fromt and back by using charming
cleansing with warm water for 1-2
minutes.
- Wipe
with a towel or toilet paper.
Caution
- If
the temperature has continuously
been set on high, there may be a
possibility of getting a burn from
the heated water.
- A
low temperature is strongly
recommended after a shower.
- If
a problem should occur, close the
pressure controller(K) on the
adapter.
- Use
of warm water over hot water is
recommended concerning the user's
health.
CARE
- Clean
frequently with a soft brush.
- Change
water tubes every 2-4 years
(Especially, hot water tube wears
easily.) Buy them head office or
local Agent by TEL. on E-mail.
Troubleshooting
| Condition |
Solution |
| Strange
sound |
Backflow
prevention device trembles.
Loosen or tighten the valve (k)
of hot or cold water adapters. |
| No
hot or cold water |
Inner
hose of bidet twists because nut
is excessively tightened when
installed. (Ask A/S.) |
| Water
is too hot. |
Close
the valve (k) of hot water
adapter. |
| No
hot water |
Boiler
does not work.
Hot water adapter is closed.
Inner hot water hose of bidet
twists. |
| Leakage |
Close
the valve (k) of Adapter (Hot,
Cold), and Ask A/S. |
|
|
Fits
Most Toilets

|
|
| |
| |
| |
|
|
| |
Have questions about our
bidet products?
Give us a call at our number (877) 852-2823 (702) 951-7256
Copyright
© 1999-2007
Cleanrite.com a division of NSV Holdings Corporation